Jordan Factory for Fire Fighting & Safety Equipment

U L FM Available

  • >> Break Away Design To prevent accidents to the Hydrants, where only the upper part of the flange to be broken on impact.
  • >> DRY BARREL DESIGN Eliminates damage to the Hydrant caused by freezing or corrosion of the upper part.
  • >> Designed as per AWWA C 502, Which applies for the wall thickness, loss of head and hose connection plugs.
  • >> Simple rugged construction & easy to maintain.
  Model 100 SF Model 150 SF
Connection Type NST

2x2.5”
1x4.0”

2x2.5” 2x2.5” or
1x4.0” 1x4.5”

Base Flange ANSI 125 RF
4.0”
6.0”
Opening Size in Hydrant Seat
3.0”
4.0”
Opening Area in Hydrant Seat
11.0 Sq. In.
12.6 Sq. In.
Inside Diameter of barrel
5.5”
6.3/8”
Barrel Area
21.3 Sq. In.
31.96 Sq. In.
Working Pressure

228.6 PSI
(16 Bars)

343.0 PSI
(24 Bars)

Testing Pressure

343.0 PSI
(24 Bars)

343.0 PSI
(24 Bars)

Weight (Approximate) for 1200 Model.
Above 120 Kg.
Above 168 Kg.

Hydrant Cabinet (Model: SHC/750 Series) Standard Equipments:

  • >> 2 Nos. – Fire Hose size 2.5”x100 Feet Synthetic Rubber Lined with NST Brass
  • >> Coupling, Aluminum Couplings available upon request.
  • >> 2 Nos. Hose Nozzle 2.5”x100 NST Thread.
  • >> 1 No. Adjustable Hydrant Wrench.
  • >> 1 No. Pin Lug Spanner Wrench.
  • >> Fire Axe.
  • >> 4 Nos. 2.5” Rubber Gasket for Hose Couplings.

Other Accessories are available on request:

  • >> Extra Fire Hose 2.5” or 1.5”. Double Jacket Hoses are also available.
  • >> Crow Bar.
  • >> Double Hydrant Gate with Ball Valve 2.5”x1.5”x1.5”.
  • >> 2.5” Underwriters Play pipe.
  • >> Flashing Lights.

Design:

Cabinet doors are made of 1.5mm steel sheet with all rounded edges.

Corrosion Protection: Cabinets are primed & painted with electrostatic powder paint oven baked to protect against rust.

Cabinet is designed to be weatherproof.

All instructions are silk screened on the Cabinet. No Sticker.

WET TYPE FIRE HYDRANTS:

Wet Fire Hydrants is used in places where there is no accidents or freezing atmospheres.

It is better to be used in Malls Shopping centers, collages, Hospitals. Etc

Features:

The pipe is made of 4” cast iron or SCH.40 Black Steel with special treatment from inside to prevent corrosion.

2 Nos. – 2.5” Hydrant angle valve with cap and chain NST American Thread.

4” BS Flange 300 PSI. Other Flanges are available up on request.